More data

This commit is contained in:
dj7nt committed 2026-10-10 16:13:58 +02:00
1 parent b168e2da43
commit 4b22f4f034
3 files changed
+97

No files matched your search

+16
View File
@@ -50,6 +50,22 @@ Register addresses were validated by probing a SE10K-RWB48BFN4 (fw 0004.0025.001
with one battery and one meter. Blocks that fail to read (flaky gateway) are
skipped for that cycle; the fields are simply absent from the point.
### Grafana dashboard
Import `grafana_dashboard.json` (Dashboards -> New -> Import). Select your
InfluxDB datasource when prompted (e.g. `InfluxDB-HJK`); the `$serial` variable
is filled from the `serialnumber` tag. InfluxQL only, InfluxDB 1.x.
The daemon also writes derived flow fields (`house_load`, `grid_import`,
`grid_export`, `battery_charge`, `battery_discharge`, `solar_to_house`) so the
dashboard's consumption-source panels are plain `mean()`/`integral()` queries.
**Sign calibration:** `meter1_power` positive = import and `battery1_power`
positive = discharge are assumptions observed once; verify on the first sunny
day (export while surplus / charge while battery fills). If inverted, flip
`METER_IMPORT_POSITIVE` / `BATTERY_DISCHARGE_POSITIVE` in
`solaredge_modbus_mqtt/__init__.py` and restart - all derived fields follow.
### Uninstall