Fix battery sign and separate PV from inverter output

Verified against simultaneous SolarEdge app readings (PV 40 W,
battery discharge 520 W, house 560 W): battery1_power negative
means discharge, and power_ac on this DC-coupled Energy Hub is
the inverter's TOTAL AC output - it already contains the battery
contribution. The old formula double-counted the battery, so
house_load collapsed (44 W shown vs 560 W real) and the PV tile
showed battery-inflated totals, which looked like PV and house
consumption were swapped.

New derived fields: house_load = power_ac + grid, and
pv_power = power_ac - battery (true PV production). Dashboard PV
tiles and both yield panels now use pv_power / integral(pv_power)
- the energy_total lifetime counter also counts battery
throughput and is not a PV yield.
This commit is contained in:
dj7nt committed 2026-10-10 17:48:23 +02:00
1 parent 412accc003
commit 0ec3bcb8ef
4 files changed
+57 -42

No files matched your search

+11 -8
View File
@@ -56,15 +56,18 @@ Import `grafana_dashboard.json` (Dashboards -> New -> Import). Select your
InfluxDB datasource when prompted (e.g. `InfluxDB-HJK`); the `$serial` variable
is filled from the `serialnumber` tag. InfluxQL only, InfluxDB 1.x.
The daemon also writes derived flow fields (`house_load`, `grid_import`,
`grid_export`, `battery_charge`, `battery_discharge`, `solar_to_house`) so the
dashboard's consumption-source panels are plain `mean()`/`integral()` queries.
The daemon also writes derived flow fields (`house_load`, `pv_power`,
`grid_import`, `grid_export`, `battery_charge`, `battery_discharge`,
`solar_to_house`) so the dashboard's consumption-source panels are plain
`mean()`/`integral()` queries.
**Sign calibration:** `meter1_power` positive = import and `battery1_power`
positive = discharge are assumptions observed once; verify on the first sunny
day (export while surplus / charge while battery fills). If inverted, flip
`METER_IMPORT_POSITIVE` / `BATTERY_DISCHARGE_POSITIVE` in
`solaredge_modbus_mqtt/__init__.py` and restart - all derived fields follow.
**Sign conventions (verified against the SolarEdge app):** `meter1_power`
positive = export, `battery1_power` negative = discharge, and `power_ac` is
the inverter's *total* AC output (PV + battery, DC-coupled Energy Hub) - which
is why `pv_power = power_ac - battery` and `house_load = power_ac + grid`.
If a different system disagrees, flip `METER_IMPORT_POSITIVE` /
`BATTERY_DISCHARGE_POSITIVE` in `solaredge_modbus_mqtt/__init__.py` and
restart - the derived fields follow.
### Uninstall
+4 -4
View File
@@ -66,7 +66,7 @@
"type": "influxdb",
"uid": "${DS_INFLUXDB}"
},
"query": "SELECT last(\"power_ac\") AS \"PV\" FROM \"$measurement\" WHERE serialnumber =~ /^$serial$/ AND $timeFilter",
"query": "SELECT last(\"pv_power\") AS \"PV\" FROM \"$measurement\" WHERE serialnumber =~ /^$serial$/ AND $timeFilter",
"refId": "A",
"rawQuery": true,
"resultFormat": "time_series"
@@ -387,7 +387,7 @@
"type": "influxdb",
"uid": "${DS_INFLUXDB}"
},
"query": "SELECT spread(\"energy_total\") / 1000 AS \"Ertrag\" FROM \"$measurement\" WHERE serialnumber =~ /^$serial$/ AND $timeFilter",
"query": "SELECT integral(\"pv_power\", 1h) / 1000 AS \"Ertrag\" FROM \"$measurement\" WHERE serialnumber =~ /^$serial$/ AND $timeFilter",
"refId": "A",
"rawQuery": true,
"resultFormat": "time_series"
@@ -808,7 +808,7 @@
"type": "influxdb",
"uid": "${DS_INFLUXDB}"
},
"query": "SELECT mean(\"power_ac\") AS \"PV\" FROM \"$measurement\" WHERE serialnumber =~ /^$serial$/ AND $timeFilter GROUP BY time($__interval) fill(null)",
"query": "SELECT mean(\"pv_power\") AS \"PV\" FROM \"$measurement\" WHERE serialnumber =~ /^$serial$/ AND $timeFilter GROUP BY time($__interval) fill(null)",
"refId": "A",
"rawQuery": true,
"resultFormat": "time_series"
@@ -1177,7 +1177,7 @@
"type": "influxdb",
"uid": "${DS_INFLUXDB}"
},
"query": "SELECT non_negative_derivative(max(\"energy_total\"), 1h) / 1000 AS \"Ertrag\" FROM \"$measurement\" WHERE serialnumber =~ /^$serial$/ AND $timeFilter GROUP BY time(1h) fill(null)",
"query": "SELECT integral(\"pv_power\", 1h) / 1000 AS \"Ertrag\" FROM \"$measurement\" WHERE serialnumber =~ /^$serial$/ AND $timeFilter GROUP BY time(1h) fill(null)",
"refId": "A",
"rawQuery": true,
"resultFormat": "time_series"
+21 -16
View File
@@ -86,13 +86,14 @@ storage_mode_map = [
"Remote Control"
]
# Observed on the probed system: meter1_power positive = grid EXPORT
# (verified against a full-battery self-consumption system: sustained +2kW
# readings at high PV were exports; a kettle appears as a negative spike).
# battery1_power positive = discharge. If day-one graphs disagree, flip here -
# all derived flow fields (house_load, grid_import, ...) follow.
# Verified against the SolarEdge app (simultaneous readings: PV 40 W, battery
# discharging 520 W, house 560 W): meter1_power positive = grid EXPORT, and
# battery1_power negative = DISCHARGE. Also established: power_ac is the
# inverter's TOTAL AC output - on this DC-coupled Energy Hub it already
# contains the battery's contribution. If a future system disagrees, flip here
# - all derived flow fields follow.
METER_IMPORT_POSITIVE = False
BATTERY_DISCHARGE_POSITIVE = True
BATTERY_DISCHARGE_POSITIVE = False
class MyInverter:
@@ -417,33 +418,37 @@ class SolarData:
@staticmethod
def _flows(d):
'''Decompose the house supply into grid/battery/solar components.
'''Decompose house supply and PV production.
power_ac is the inverter's TOTAL AC output and already contains the
battery's contribution (DC-coupled Energy Hub), so:
pv_power = power_ac - battery (discharge-positive)
house_load = power_ac + grid
Computed at ingest because all fields land in one InfluxDB point and
InfluxQL cannot clip series (max(x, 0)) or split them afterwards -
dashboard queries stay plain mean()/integral().
'''
pv = d.get('power_ac')
grid = d.get('meter1_power')
batt = d.get('battery1_power')
if pv is None or grid is None or batt is None:
pv_ac = d.get('power_ac')
meter = d.get('meter1_power')
batt_raw = d.get('battery1_power')
if pv_ac is None or meter is None or batt_raw is None:
return {}
if not METER_IMPORT_POSITIVE:
grid = -grid
if not BATTERY_DISCHARGE_POSITIVE:
batt = -batt
grid = meter if METER_IMPORT_POSITIVE else -meter # + = import
batt = batt_raw if BATTERY_DISCHARGE_POSITIVE else -batt_raw # + = discharge
load = pv + grid + batt
load = pv_ac + grid
grid_import = max(grid, 0.0)
grid_export = max(-grid, 0.0)
battery_discharge = max(batt, 0.0)
battery_charge = max(-batt, 0.0)
pv_power = max(pv_ac - batt, 0.0)
solar_to_house = max(load - grid_import - battery_discharge, 0.0)
return {
# + 0.0 normalizes -0.0 from max(-x, 0.0)
'house_load': round(max(load, 0.0), 4) + 0.0,
'pv_power': round(pv_power, 4) + 0.0,
'grid_import': round(grid_import, 4) + 0.0,
'grid_export': round(grid_export, 4) + 0.0,
'battery_discharge': round(battery_discharge, 4) + 0.0,
+21 -14
View File
@@ -209,32 +209,39 @@ class TestSolarData(unittest.TestCase):
self.assertNotIn('storage_control_mode', solarData.data)
self.assertAlmostEqual(597.0, solarData.data['power_ac'])
def testFlowsImport(self):
# kettle: PV 861.2 W, grid meter reads -689.5 (import), battery idle
solarData = SolarData(probe_data(power_ac=8612, m1_power=-6895, b1_power=0.0))
def testFlowsNightDischarge(self):
# ground truth from the SolarEdge app: PV 40 W, battery discharging
# 520 W, house 560 W, grid ~0. power_ac (529) = PV + battery output.
solarData = SolarData(probe_data(power_ac=5290, m1_power=0, b1_power=-485.0))
self.assertAlmostEqual(1550.7, solarData.data['house_load'])
self.assertAlmostEqual(689.5, solarData.data['grid_import'])
self.assertAlmostEqual(0.0, solarData.data['grid_export'])
self.assertAlmostEqual(529.0, solarData.data['house_load'])
self.assertAlmostEqual(44.0, solarData.data['pv_power'])
self.assertAlmostEqual(485.0, solarData.data['battery_discharge'])
self.assertAlmostEqual(0.0, solarData.data['battery_charge'])
self.assertAlmostEqual(0.0, solarData.data['battery_discharge'])
self.assertAlmostEqual(861.2, solarData.data['solar_to_house'])
self.assertAlmostEqual(0.0, solarData.data['grid_import'])
self.assertAlmostEqual(44.0, solarData.data['solar_to_house'])
def testFlowsExport(self):
# observed afternoon: PV 5000, exporting 2000, charging battery with 1000
solarData = SolarData(probe_data(power_ac=50000, m1_power=20000, b1_power=-1000.0))
def testFlowsSurplus(self):
# PV 5000, charging battery with 1000, exporting 2000, house 2000.
# Charging happens on the DC side: power_ac only carries 4000.
solarData = SolarData(probe_data(power_ac=40000, m1_power=20000, b1_power=1000.0))
self.assertAlmostEqual(2000.0, solarData.data['house_load'])
self.assertAlmostEqual(5000.0, solarData.data['pv_power'])
self.assertAlmostEqual(0.0, solarData.data['grid_import'])
self.assertAlmostEqual(2000.0, solarData.data['grid_export'])
self.assertAlmostEqual(1000.0, solarData.data['battery_charge'])
self.assertAlmostEqual(0.0, solarData.data['battery_discharge'])
self.assertAlmostEqual(2000.0, solarData.data['solar_to_house'])
def testFlowsNightDischarge(self):
solarData = SolarData(probe_data(power_ac=0, m1_power=0, b1_power=300.0))
def testFlowsImport(self):
# no sun: battery covers 300 W of the house, 200 W imported.
# power_ac = 300 (battery output), meter reads -200 (import).
solarData = SolarData(probe_data(power_ac=3000, m1_power=-2000, b1_power=-300.0))
self.assertAlmostEqual(300.0, solarData.data['house_load'])
self.assertAlmostEqual(500.0, solarData.data['house_load'])
self.assertAlmostEqual(0.0, solarData.data['pv_power'])
self.assertAlmostEqual(200.0, solarData.data['grid_import'])
self.assertAlmostEqual(300.0, solarData.data['battery_discharge'])
self.assertAlmostEqual(0.0, solarData.data['solar_to_house'])