Read all registers at once
When you read the registers one-by-one, which is what the solaredge_mobus library is doing, you run into the issue where the value and the scale are sometimes out of sync. This happens mostly when the values go up or down a lot, like at the beginning and at the end of the day. At these times the SolarEdge inverter can change the scale of the values it's returning. When you read the value register, the scale might be -2, but in the time between that request, and the request for the scale, the inverter has changed the scale to -3. So in the next register read, you will get -3 for the scale, but have a value in the scale of -2. Now when you do the value calculation, you end up with a factor 10 difference. So it's better, and also _much_ faster to read out all the registers at once and then parse the values from this bigger read out. I'm planning to do a MR back to solaredge_modbus with this change, so for now i've just included that code into this project.
This commit is contained in:
2 files changed
+247
-2
No files matched your search
@@ -9,6 +9,7 @@ import time
|
||||
import paho.mqtt.client as mqtt
|
||||
import yaml
|
||||
from solaredge_modbus_mqtt import SolarData
|
||||
from solaredge_modbus_mqtt import MyInverter
|
||||
from pymodbus.exceptions import ConnectionException
|
||||
|
||||
if __name__ == '__main__':
|
||||
@@ -30,7 +31,7 @@ if __name__ == '__main__':
|
||||
print('Cannot connect to MQTT on {0}:{1}, error: {2}'.format(config['mqtt']['host'], config['mqtt']['port'], err))
|
||||
sys.exit(1)
|
||||
|
||||
inverter = solaredge_modbus.Inverter(
|
||||
inverter = MyInverter(
|
||||
host=config['modbus']['host'],
|
||||
port=config['modbus']['port'],
|
||||
timeout=config['modbus']['timeout'],
|
||||
@@ -41,7 +42,8 @@ if __name__ == '__main__':
|
||||
publishedAutoDiscovery = False
|
||||
while run:
|
||||
try:
|
||||
solar_data = SolarData(inverter.read_all())
|
||||
raw = inverter.read()
|
||||
solar_data = SolarData(raw)
|
||||
except ConnectionException as err:
|
||||
print('Cannot connect to SolarEdge Modbus server on {0}:{1}, error: {2}'.format(config['modbus']['host'], config['modbus']['port'], err))
|
||||
sys.exit(2)
|
||||
|
||||
@@ -1,4 +1,243 @@
|
||||
import math
|
||||
import enum
|
||||
|
||||
from pymodbus.constants import Endian
|
||||
from pymodbus.payload import BinaryPayloadDecoder
|
||||
from pymodbus.client.sync import ModbusTcpClient
|
||||
from pymodbus.client.sync import ModbusSerialClient
|
||||
from pymodbus.register_read_message import ReadHoldingRegistersResponse
|
||||
|
||||
|
||||
RETRIES = 3
|
||||
TIMEOUT = 1
|
||||
UNIT = 1
|
||||
|
||||
|
||||
class inverterDID(enum.Enum):
|
||||
SINGLE_PHASE = 101
|
||||
SPLIT_PHASE = 102
|
||||
THREE_PHASE = 103
|
||||
|
||||
|
||||
class inverterStatus(enum.Enum):
|
||||
I_STATUS_OFF = 1
|
||||
I_STATUS_SLEEPING = 2
|
||||
I_STATUS_STARTING = 3
|
||||
I_STATUS_MPPT = 4
|
||||
I_STATUS_THROTTLED = 5
|
||||
I_STATUS_SHUTTING_DOWN = 6
|
||||
I_STATUS_FAULT = 7
|
||||
I_STATUS_STANDBY = 8
|
||||
|
||||
|
||||
class connectionType(enum.Enum):
|
||||
RTU = 1
|
||||
TCP = 2
|
||||
|
||||
|
||||
class registerType(enum.Enum):
|
||||
INPUT = 1
|
||||
HOLDING = 2
|
||||
|
||||
|
||||
class registerDataType(enum.Enum):
|
||||
BITS = 1
|
||||
UINT8 = 2
|
||||
UINT16 = 3
|
||||
UINT32 = 4
|
||||
UINT64 = 5
|
||||
INT8 = 6
|
||||
INT16 = 7
|
||||
INT32 = 8
|
||||
INT64 = 9
|
||||
FLOAT16 = 10
|
||||
FLOAT32 = 11
|
||||
STRING = 12
|
||||
|
||||
|
||||
sunspec_notimplemented = {
|
||||
"UINT16": 0xffff,
|
||||
"ACC16": 0x0000,
|
||||
"UINT32": 0xffffffff,
|
||||
"ACC32": 0x00000000,
|
||||
"UINT64": 0xffffffffffffffff,
|
||||
"ACC64": 0x0000000000000000,
|
||||
"INT16": 0x8000,
|
||||
"SCALE": 0x8000,
|
||||
"INT32": 0x80000000,
|
||||
"INT64": 0x8000000000000000,
|
||||
"FLOAT": 0x7fc00000,
|
||||
"STRING": "\x00"
|
||||
}
|
||||
|
||||
c_sunspec_did_map = {
|
||||
"101": "Single Phase",
|
||||
"102": "Split Phase",
|
||||
"103": "Three Phase"
|
||||
}
|
||||
|
||||
inverter_status_map = [
|
||||
"Undefined",
|
||||
"Off",
|
||||
"Sleeping",
|
||||
"Grid Monitoring",
|
||||
"Producing",
|
||||
"Producing (Throttled)",
|
||||
"Shutting Down",
|
||||
"Fault",
|
||||
"Standby"
|
||||
]
|
||||
|
||||
|
||||
class MyInverter:
|
||||
|
||||
model = "SolarEdge"
|
||||
stopbits = 1
|
||||
parity = "N"
|
||||
baud = 115200
|
||||
|
||||
registers = (
|
||||
("c_model", 40020, 16, registerType.HOLDING, registerDataType.STRING, str, "Model", ""),
|
||||
("c_version", 40044, 8, registerType.HOLDING, registerDataType.STRING, str, "Version", ""),
|
||||
("c_serialnumber", 40052, 16, registerType.HOLDING, registerDataType.STRING, str, "Serial", ""),
|
||||
("c_deviceaddress", 40068, 1, registerType.HOLDING, registerDataType.UINT16, int, "Modbus ID", ""),
|
||||
("c_sunspec_did", 40069, 1, registerType.HOLDING, registerDataType.UINT16, int, "SunSpec DID", c_sunspec_did_map),
|
||||
("current", 40071, 1, registerType.HOLDING, registerDataType.UINT16, int, "Current", "A"),
|
||||
("p1_current", 40072, 1, registerType.HOLDING, registerDataType.UINT16, int, "P1 Current", "A"),
|
||||
("p2_current", 40073, 1, registerType.HOLDING, registerDataType.UINT16, int, "P2 Current", "A"),
|
||||
("p3_current", 40074, 1, registerType.HOLDING, registerDataType.UINT16, int, "P3 Current", "A"),
|
||||
("current_scale", 40075, 1, registerType.HOLDING, registerDataType.INT16, int, "Current Scale Factor", ""),
|
||||
("p1_voltage", 40076, 1, registerType.HOLDING, registerDataType.UINT16, int, "P1 Voltage", "V"),
|
||||
("p2_voltage", 40077, 1, registerType.HOLDING, registerDataType.UINT16, int, "P2 Voltage", "V"),
|
||||
("p3_voltage", 40078, 1, registerType.HOLDING, registerDataType.UINT16, int, "P3 Voltage", "V"),
|
||||
("p1n_voltage", 40079, 1, registerType.HOLDING, registerDataType.UINT16, int, "P1-N Voltage", "V"),
|
||||
("p2n_voltage", 40080, 1, registerType.HOLDING, registerDataType.UINT16, int, "P2-N Voltage", "V"),
|
||||
("p3n_voltage", 40081, 1, registerType.HOLDING, registerDataType.UINT16, int, "P3-N Voltage", "V"),
|
||||
("voltage_scale", 40082, 1, registerType.HOLDING, registerDataType.INT16, int, "Voltage Scale Factor", ""),
|
||||
("power_ac", 40083, 1, registerType.HOLDING, registerDataType.INT16, int, "Power", "W"),
|
||||
("power_ac_scale", 40084, 1, registerType.HOLDING, registerDataType.INT16, int, "Power Scale Factor", ""),
|
||||
("frequency", 40085, 1, registerType.HOLDING, registerDataType.UINT16, int, "Frequency", "Hz"),
|
||||
("frequency_scale", 40086, 1, registerType.HOLDING, registerDataType.INT16, int, "Frequency Scale Factor", ""),
|
||||
("power_apparent", 40087, 1, registerType.HOLDING, registerDataType.INT16, int, "Power (Apparent)", "VA"),
|
||||
("power_apparent_scale", 40088, 1, registerType.HOLDING, registerDataType.INT16, int, "Power (Apparent) Scale Factor", ""),
|
||||
("power_reactive", 40089, 1, registerType.HOLDING, registerDataType.INT16, int, "Power (Reactive)", "VA"),
|
||||
("power_reactive_scale", 40090, 1, registerType.HOLDING, registerDataType.INT16, int, "Power (Reactive) Scale Factor", ""),
|
||||
("power_factor", 40091, 1, registerType.HOLDING, registerDataType.INT16, int, "Power Factor", "%"),
|
||||
("power_factor_scale", 40092, 1, registerType.HOLDING, registerDataType.INT16, int, "Power Factor Scale Factor", ""),
|
||||
("energy_total", 40093, 2, registerType.HOLDING, registerDataType.UINT32, int, "Total Energy", "Wh"),
|
||||
("energy_total_scale", 40095, 1, registerType.HOLDING, registerDataType.UINT16, int, "Total Energy Scale Factor", ""),
|
||||
("current_dc", 40096, 1, registerType.HOLDING, registerDataType.UINT16, int, "DC Current", "A"),
|
||||
("current_dc_scale", 40097, 1, registerType.HOLDING, registerDataType.INT16, int, "DC Current Scale Factor", ""),
|
||||
("voltage_dc", 40098, 1, registerType.HOLDING, registerDataType.UINT16, int, "DC Voltage", "V"),
|
||||
("voltage_dc_scale", 40099, 1, registerType.HOLDING, registerDataType.INT16, int, "DC Voltage Scale Factor", ""),
|
||||
("power_dc", 40100, 1, registerType.HOLDING, registerDataType.INT16, int, "DC Power", "W"),
|
||||
("power_dc_scale", 40101, 1, registerType.HOLDING, registerDataType.INT16, int, "DC Power Scale Factor", ""),
|
||||
("temperature", 40103, 1, registerType.HOLDING, registerDataType.INT16, int, "Temperature", "°C"),
|
||||
("temperature_scale", 40106, 1, registerType.HOLDING, registerDataType.INT16, int, "Temperature Scale Factor", ""),
|
||||
("status", 40107, 1, registerType.HOLDING, registerDataType.UINT16, int, "Status", inverter_status_map),
|
||||
("vendor_status", 40108, 1, registerType.HOLDING, registerDataType.UINT16, int, "Vendor Status", ""),
|
||||
)
|
||||
|
||||
def __init__(
|
||||
self, host=False, port=False,
|
||||
device=False, stopbits=False, parity=False, baud=False,
|
||||
timeout=TIMEOUT, retries=RETRIES, unit=UNIT
|
||||
):
|
||||
self.host = host
|
||||
self.port = port
|
||||
self.device = device
|
||||
|
||||
self.firstRegister = self.registers[0][1]
|
||||
self.registerLength = (self.registers[-1][1]+self.registers[-1][2]) - self.registers[0][1]
|
||||
|
||||
if stopbits:
|
||||
self.stopbits = stopbits
|
||||
|
||||
if parity:
|
||||
self.parity = parity
|
||||
|
||||
if baud:
|
||||
self.baud = baud
|
||||
|
||||
self.timeout = timeout
|
||||
self.retries = retries
|
||||
self.unit = unit
|
||||
|
||||
if device:
|
||||
self.mode = connectionType.RTU
|
||||
self.client = ModbusSerialClient(
|
||||
method="rtu",
|
||||
port=self.device,
|
||||
stopbits=self.stopbits,
|
||||
parity=self.parity,
|
||||
baudrate=self.baud,
|
||||
timeout=self.timeout)
|
||||
else:
|
||||
self.mode = connectionType.TCP
|
||||
self.client = ModbusTcpClient(
|
||||
host=self.host,
|
||||
port=self.port,
|
||||
timeout=self.timeout
|
||||
)
|
||||
|
||||
def __repr__(self):
|
||||
if self.mode == connectionType.RTU:
|
||||
return f"{self.model}({self.device}, {self.mode}: stopbits={self.stopbits}, parity={self.parity}, baud={self.baud}, timeout={self.timeout}, unit={hex(self.unit)})"
|
||||
elif self.mode == connectionType.TCP:
|
||||
return f"{self.model}({self.host}:{self.port}, {self.mode}: timeout={self.timeout}, unit={hex(self.unit)})"
|
||||
else:
|
||||
return f"<{self.__class__.__module__}.{self.__class__.__name__} object at {hex(id(self))}>"
|
||||
|
||||
def _read_holding_registers(self, address, length):
|
||||
for i in range(self.retries):
|
||||
result = self.client.read_holding_registers(address=address, count=length, unit=self.unit)
|
||||
|
||||
if isinstance(result, ReadHoldingRegistersResponse):
|
||||
return BinaryPayloadDecoder.fromRegisters(result.registers, byteorder=Endian.Big, wordorder=Endian.Big)
|
||||
|
||||
return None
|
||||
|
||||
def _decode_value(self, data, length, dtype, vtype):
|
||||
try:
|
||||
if dtype == registerDataType.UINT16:
|
||||
decoded = data.decode_16bit_uint()
|
||||
elif dtype == registerDataType.UINT32:
|
||||
decoded = data.decode_32bit_uint()
|
||||
elif dtype == registerDataType.INT16:
|
||||
decoded = data.decode_16bit_int()
|
||||
elif dtype == registerDataType.STRING:
|
||||
decoded = data.decode_string(length * 2).decode("utf-8").replace("\x00", "")
|
||||
else:
|
||||
raise NotImplementedError(dtype)
|
||||
|
||||
if decoded == sunspec_notimplemented[dtype.name]:
|
||||
return False
|
||||
else:
|
||||
return vtype(decoded)
|
||||
except NotImplementedError:
|
||||
raise
|
||||
|
||||
def connected(self):
|
||||
return bool(self.client.connect())
|
||||
|
||||
def read(self):
|
||||
rawData = self._read_holding_registers(self.firstRegister, self.registerLength)
|
||||
data = {}
|
||||
|
||||
offset = self.firstRegister
|
||||
for register in self.registers:
|
||||
name, address, length, rtype, dtype, vtype, label, fmt = register
|
||||
|
||||
if (address > offset):
|
||||
bytesToSkip = address - offset
|
||||
offset += bytesToSkip
|
||||
rawData.skip_bytes(bytesToSkip*2)
|
||||
|
||||
data[name] = self._decode_value(rawData, length, dtype, vtype)
|
||||
offset += length
|
||||
|
||||
return data
|
||||
|
||||
|
||||
class SolarData:
|
||||
|
||||
@@ -44,6 +283,10 @@ class SolarData:
|
||||
result = {}
|
||||
|
||||
for fieldName, config in self.fields.items():
|
||||
dataField = config['field'] if 'field' in config else fieldName
|
||||
if dataField not in data:
|
||||
continue
|
||||
|
||||
value = data[config['field']] if 'field' in config else data[fieldName]
|
||||
|
||||
if 'scaleField' in config:
|
||||
|
||||
Reference in new issue