dj7nt b168e2da43 Replace MQTT output with direct InfluxDB writes
Polls now cover meter 1, battery 1 and storage control blocks,
plus inverter event registers for off-grid detection (vendor
event bit 0). Register layout validated by probing a
SE10K-RWB48BFN4 with fw 0004.0025.0011; battery and storage
floats are word-swapped on this device.

Failed Influx writes spool to disk and replay on the next
success (Influx reached over WAN). Modbus blocks that fail to
read are skipped for that cycle; the flaky gateway must not
kill the daemon. Battery lifetime counters at 0xE176/0xE17A
hang the device and are never read.

BREAKING CHANGE: config.yaml 'mqtt:' section replaced by
'influx:', Home Assistant discovery removed.
2026-10-10 15:42:48 +02:00

83 lines
2.7 KiB
Python
Executable File

#!/usr/bin/env python3
import argparse
import base64
import os
import sys
import time
import urllib.parse
import urllib.request
import yaml
from pymodbus.exceptions import ConnectionException
from solaredge_modbus_mqtt import MyInverter
from solaredge_modbus_mqtt import SolarData
from solaredge_modbus_mqtt import to_line_protocol
SPOOL_FILE = 'spool.txt'
SPOOL_MAX_LINES = 20000 # ~16h of backlog at a 3s poll interval
def send_to_influx(lines, influx):
url = '{0}/write?db={1}&precision=ns'.format(
influx['url'].rstrip('/'),
urllib.parse.quote(influx['db'], safe='')
)
request = urllib.request.Request(url, data='\n'.join(lines).encode('utf-8'), method='POST')
if influx.get('user'):
credentials = '{0}:{1}'.format(influx['user'], influx.get('pass') or '')
token = base64.b64encode(credentials.encode('utf-8')).decode('utf-8')
request.add_header('Authorization', 'Basic ' + token)
urllib.request.urlopen(request, timeout=5)
def publish(line, influx):
'''Write one line to InfluxDB. On failure, spool it to disk and replay the
spool together with the next successful write (capped at SPOOL_MAX_LINES).'''
try:
backlog = []
if os.path.exists(SPOOL_FILE):
with open(SPOOL_FILE, 'r') as f:
backlog = f.read().splitlines()[-SPOOL_MAX_LINES:]
send_to_influx(backlog + [line], influx)
if backlog:
os.remove(SPOOL_FILE)
except Exception as err:
print('InfluxDB write failed, spooling line: {0}'.format(err))
with open(SPOOL_FILE, 'a') as f:
f.write(line + '\n')
if __name__ == '__main__':
argparser = argparse.ArgumentParser()
argparser.add_argument('--config', type=str, default=os.environ.get('CONFIG_FILE', 'config.yaml'), help='Path to the config.yaml')
args = argparser.parse_args()
with open(args.config, 'r') as stream:
try:
config = yaml.safe_load(stream)
except yaml.YAMLError as exc:
print(exc)
sys.exit(1)
inverter = MyInverter(
host=config['modbus']['host'],
port=config['modbus']['port'],
timeout=config['modbus']['timeout'],
unit=config['modbus']['unit']
)
while True:
try:
raw = inverter.read()
solar_data = SolarData(raw)
line = to_line_protocol(solar_data.data, config['influx'].get('measurement', 'solaredge'))
if line:
publish(line, config['influx'])
except ConnectionException as err:
print('Cannot connect to SolarEdge Modbus server on {0}:{1}, error: {2}'.format(
config['modbus']['host'], config['modbus']['port'], err))
time.sleep(config['poll_interval'])